CONFIGURABLE INPUT DATA DEFINITION

This section defines the EGPWS input signal characteristics or data word formats for input signals commonly used in
MK VI and VIII EGPWS applications. See Section 5 for specific information on signal usage.

6.1 Analog Input Data
6.1.1 ARINC 552 Radio Altimeter

Data Item

Value

Signal Name:

Radio Altitude, ARINC 552

AIC Algorithm:

ARINC 552A Radio Altitude

Signal Dynamic Range:

–100 to +3566 Feet

Signal Reasonable Range:

–30 to +2800 Feet

Signal Open Wire Threshold

–50 Feet

Reference Dynamic Range:

None

Reference Reasonable Range:

None

Scale:

For Radio Altitude

480 feet:

Volts

in

= (0.02 * RALT (ft)) + 0.4

For Radio Altitude > 480 feet:

Volts

in

=

))

500

20

+

(ft)

RALT

(

Ln

+

(1

10

×

Input Signal Connection:

(+) = J1-64, (–) = J1-45

Input Reference Connection:

None

AIC Name:

D1 (DC1)

External Validity Flag Connection:

J1-29

AIC LSB:

0.25 Feet

AIC Status Mask:

0000200C

External Validity Type:

Discrete Validity

6.1.2 ALT 55 Radio Altimeter

Data Item

Value

Signal Name:

Radio Altitude, ALT 55

AIC Algorithm:

DC Absolute

Signal Dynamic Range:

–100 to +3200 Feet

Signal Reasonable Range:

–30 to +2800 Feet

Signal Open Wire Threshold

–50 Feet

Reference Dynamic Range:

None

Reference Reasonable Range:

None

Scale:

For Radio Altitude

500 Feet (

10.4 VDC):

Volts

in

= (0.02 * RALT) + 0.4 or

RALT (ft) = 50 ft/VDC * Volts

in

– 20 ft

For Radio Altitude > 500 feet (> 10.4 VDC):

Volts

in

= 0.003 * (RALT –500) + 10.4 or

RALT (ft) = 333.3333 ft/VDC * Volts

in

– 2966.7

Input Signal Connection:

(+) = J1-64, (–) = J1-45

Input Reference Connection:

None

AIC Name:

D1 (DC1)

External Validity Flag Connection:

J1-29

AIC LSB:

0.25 Feet

AIC Status Mask:

0000200C

External Validity Type:

Discrete Validity