6.1.3 Uncorrected Barometric Altitude

Data Item

Value

Signal Name:

Uncorrected Baro Altitude, DC Voltage

AIC Algorithm:

DC Absolute

Signal Dynamic Range:

–19,334 to +31,166 Feet

Signal Reasonable Range:

–1500 to +30,000 Feet

Signal Open Wire Threshold

–3000 Feet

Reference Dynamic Range:

None

Reference Reasonable Range:

None

Scale:

Altitude (Feet) = 3150 Feet/VDC * Volts – 17250 Feet

Input Signal Connection:

(+) = J1-62, (–) = J1-43

Input Reference Connection:

None

AIC Name:

D2 (DC2)

External Validity Flag Connection:

J1-9

AIC LSB:

2 Feet

AIC Status Mask:

0000200F

External Validity Type:

Discrete Validity

6.1.4 Outside Air Temperature (500 ohm probe)

Data Item

Value

Signal Name:

Outside Air Temperature, DC Signal

AIC Algorithm:

DC Absolute

Signal Dynamic Range:

–85 to +60 °C

Signal Reasonable Range:

–70 to +60 °C

Signal Open Wire Threshold

–80 °C

Reference Dynamic Range:

None

Reference Reasonable Range:

None

Scale:

V

OAT

OAT (in °C)

< 0.43448

525.50676* V

OAT

– 268.805

>= 0.43448 and < 0.49212

545.64369* V

OAT

– 277.560

>= 0.49212 and < 0.54816

566.02357* V

OAT

– 287.594

>= 0.54816

581.96990* V

OAT

– 296.270

Input Signal Connection:

(+) = J1-63, (–) = J1-44 (see section 5.3.2 for hookup)

Input Reference Connection:

None

AIC Name:

D5 (DC5)

External Validity Flag Connection:

None

AIC LSB:

0.03125

°

C

AIC Status Mask:

0000200F

External Validity Type:

None

6.1.5 Outside Air Temperature (Internal Constant)

Data Item

Value

Signal Name:

Outside Air Temperature, DC Signal

AIC Algorithm:

DC Absolute

Signal Dynamic Range:

Constant, no external connection

Signal Reasonable Range:

Constant, no external connection

Signal Open Wire Threshold

None

Reference Dynamic Range:

None

Reference Reasonable Range:

None

Scale:

OAT (in °C) = 25°C Constant

Input Signal Connection:

(no external connection)

Input Reference Connection:

None

AIC Name:

None