Uncorrected barometric altitude (az-241, az-800) – Honeywell MK VI User Manual

Page 275

Advertising
background image

Honeywell

MK VI MK VIII EGPWS Installation Design Guide

Proprietary notice on title page applies

CAGE CODE: 97896

SCALE: NONE

SIZE: A

DWG NO: 060-4314-150

REV:

SHEET

275

6.1.14 ARINC 547/578-4 Low Level Glideslope Deviation Validity

Data Item

Value

Signal Name:

Low Level Glideslope Validity, DC Signal

AIC Algorithm:

DC Absolute

Signal Dynamic Range:

–1.1 to +1.5 VDC

Signal Reasonable Range:

–0.5 to +1.5 VDC

Signal Open Wire Threshold

–1 VDC

Reference Dynamic Range:

None

Reference Reasonable Range:

None

Scale:

GS Validity (VDC) = Volts

in

Input Signal Connection:

(+) = J1-30, (–) = J1-10

Input Reference Connection:

None

AIC Name:

D4 (DC4)

External Validity Flag Connection:

None

AIC LSB:

0.0012207 VDC

AIC Status Mask:

0000200C

External Validity Type:

None

6.1.15 Roll Attitude, 3 Wire Synchro (11.8 VAC ) with Validity

Data Item

Value

Signal Name:

Roll Attitude, 3 Wire Synchro

AIC Algorithm:

3 Wire Synchro (11.8 VAC)

Signal Dynamic Range:

±90° Synchro Angle (15.5 VAC max)

Signal Reasonable Range:

±80° Synchro Angle

Signal Open Wire Threshold

None

Reference Dynamic Range:

None

Reference Reasonable Range:

None

Scale:

Roll Angle (deg) = 1 deg/deg

Input Signal Connection:

(X) = J1-1, (Y) = J1-21, (Z) = J1-2

Input Reference Connection:

None

AIC Name:

S1 (Synchro #1)

External Validity Flag Connection:

J1-68

AIC FIFO LSB:

0.00549316

°

AIC Status Mask:

0000010F

External Validity Type:

Discrete Validity

6.1.16 Uncorrected Barometric Altitude (AZ-241, AZ-800)

Data Item

Value

Signal Name:

Uncorrected Baro Altitude, DC Voltage

AIC Algorithm:

DC Absolute

Signal Dynamic Range:

–3750 to +52,750 Feet (0.0 Vdc to +11.30 Vdc)

Signal Reasonable Range:

–1000 to +50,000 Feet (+0.55 Vdc to +10.75 Vdc)

Signal Open Wire Threshold

–1950 Feet (+0.36 Vdc)

Reference Dynamic Range:

None

Reference Reasonable Range:

None

Scale:

Altitude (Feet) = 5000 Feet/VDC * Volts – 3750
(0.2 mVdc/foot, 0.75 Vdc = 0 feet)

Input Signal Connection:

(+) = J1-62, (–) = J1-43

AIC Name:

D2 (DC2)

Input Reference Connection:

None

External Validity Flag Connection:

J1-9

Advertising
This manual is related to the following products: