CONTROL WORD 2 BIT ASSIGNMENTS

Bit No.

DEFINITION

11–22

Spares

23

Display Range Divide by 20

24 – 29

Display Range as specified in the table below

BITS 24 to 29 = Display Range (5 to 320NM, format as follows)

Bit 29

Bit 28

Bit 27

Bit 26

Bit 25

Bit 24

RANGE

0

0

0

0

0

0

320 NM

0

0

0

0

0

1

5 NM

0

0

0

0

1

0

10 NM

0

0

0

1

0

0

20 NM

0

0

1

0

0

0

40 NM

0

1

0

0

0

0

80 NM

1

0

0

0

0

0

160 NM

Note: The range bits are additive; e.g., if bits 24 and 26 = 1 then the range would be 25 NM.

6.2.21 Discrete Word (155 or 176) - MFD

DISCRETE WORD – MFD

Source: MFD or IOC #1 & IOC #2

LABEL (Octal) 155 or 176

Units: N/A

Max. Range: N/A

Approx. LSB: N/A

Data Bits: Discrete word, see below

+ = N/A

Sign Bit: N/A

Pad Bits: 9, 10

Transmit Interval (mSec): 50 ms

Data Type: Discrete

SDI Bits: N/A

DAU WORD BIT ASSIGNMENTS

Bit No.

DEFINITION

11 - 17

Not Used by EGPWC

18 - 24

Terrain Display Range as specified in the table below

25 - 29

Not Used by EGPWC

BITS 18 to 24 = Display Range (5 to 640 NM, Format as follows)

DISPLAY RANGE BIT ASSIGNMENTS

Bits 24-18 DEFINITION

Bits 24-18 DEFINITION

All 7 bits zero: 640 NM

Bit 21 set: 40 NM

Bit 18 set: 5 NM

Bit 22 set: 80 NM

Bit 19 set: 10 NM

Bit 23 set: 160 NM

Bit 20 set: 20 NM

Bit 24 set: 320 NM

6.2.22 Hazard Range Output (077)

Hazard Range Output - Wx RADAR

Source: Wx Radar

LABEL (Octal) 077

Units: N/A

Max. Range: N/A

Approx. LSB: N/A

Data Bits: Discrete word, see below

+ = N/A

Sign Bit: N/A

Pad Bits: 9, 10

Transmit Interval (mSec): 20 ms

Data Type: Discrete (non-standard SSM, see below)

SDI Bits: N/A

HAZARD RANGE OUTPUT BIT ASSIGNMENTS

Bit No.

DEFINITION

11

Event Number LSB, Not Used by EGPWC

12

Event Number, Not Used by EGPWC

13

Event Number MSB, Not Used by EGPWC

14

Range (Start), 0.0625 NM, Not Used by EGPWC

15

Range (Start), 0.125 NM, Not Used by EGPWC