Discrete word \(273\) – bendix weather radar v, Discrete word \(275\) – ic600 only, Radio altitude (164) – Honeywell MK VI User Manual

Page 285: Glideslope deviation (174 or 117)

Advertising
background image

Honeywell

MK VI MK VIII EGPWS Installation Design Guide

Proprietary notice on title page applies

CAGE CODE: 97896

SCALE: NONE

SIZE: A

DWG NO: 060-4314-150

REV:

SHEET

285

Bits 14 to 16 = Mode, format as follows

Bit 16

Bit 15

Bit 14

MODE

0

0

0

Standby

0

0

1

Weather Only

0

1

0

Map Only

0

1

1

Windshear Hazard Factor

1

0

0

Test

1

0

1

Windshear and Turbulence

1

1

0

Weather and Turbulence

1

1

1

Windshear Icon

6.2.27 Discrete Word (273) – Bendix Weather Radar Vertical Profile Mode

Discrete Word

Source: EFIS/Weather Radar

LABEL (Octal) 273

Units: N/A

Max. Range: N/A

Approx. LSB: N/A

Data Bit: 11

+ = N/A

Sign Bit: N/A

Pad Bits: N/A

Transmit Interval (mSec): 100 ms

Data Type: Discrete

SDI Bits: 9, 10

Some display systems support a vertical profile WXR display where the radar scans up and down. This mode can not
support a terrain display. Therefore when this mode bit is set (indicating that the profile mode is active) the EGPWS is to
treat this as a non-displayable mode.

Mode

bit 11

Displayable

Vertical Profile On

1

No

Vertical Profile Off

0

Yes

6.2.28 Discrete Word (275) – IC600 only

Discrete Word - (IC600 Packed Discrete Word 4)

Source: IC

LABEL (Octal) 275

Units: N/A

Max. Range: N/A

Approx. LSB: N/A

Data Bits: Bit 17: See TABLE

+ = N/A

Sign Bit: N/A

Pad Bits: N/A

Transmit Interval (mSec): 500 ms

Data Type: Discrete

SDI Bits: 9, 10

BIT ASSIGNMENTS

Discrete Data

Bit Definition

IC outputting MFD format
(its range is displayed)

Bit 17 = 1: IC Driving Display
Bit 17 = 0: IC not Driving Display

6.2.29 Radio Altitude (164)

RADIO ALTITUDE

Source: ARINC 707 LRRA or IOC

LABEL (Octal) 164

Units: Feet

Max. Range:

±

8,192 Feet

Approx. LSB: 0.125 Foot

Data Bits: 13 to 28 = 16

+ = Above Ground Level (AGL)

Sign Bit: 29

Pad Bits: 11, 12

Transmit Interval (mSec): 25 to 50

Data Type: 2’s Complement Binary

SDI Bits: 9, 10

6.2.30 Glideslope Deviation (174 or 117)

GLIDESLOPE DEVIATION

Source: ARINC 710 ILS or IOC

LABEL (Octal) 174 or 117

Units: See NOTE

Max. Range:

±

0.8 DDM

Approx. LSB: 0.000195 DDM

Data Bits: 17 to 28 = 12

+ = Fly Down = Above Beam C/L

Sign Bit: 29

Pad Bits: 11 to 16

Transmit Interval (mSec): 33.3 to 66.6

Data Type: 2’s Complement Binary

SDI Bits: 9, 10

NOTE: Units = Difference in Depth of Modulation (DDM) 0.0875 DDM = 1 ‘Dot’.