6.2.43 Longitudinal Acceleration (331)

LONGITUDINAL ACCELERATION

Source: IOC

LABEL (Octal) 331

Units: g’s

Max. Range: +/-4.0 g’s

Approx. LSB: 0.000977 g’s

Data Bits: 17 to 28 = 12

+ = Forward

Sign Bit: 29

Pad Bits: 11 to 16

Transmit Interval (mSec): 10 to 20

Data Type: 2’s Complement Binary

SDI Bits: 9, 10

6.2.44 Left Body Angle of Attack (224)

Body Angle of Attack

Source: IOC

LABEL (Octal) 224

Units: degrees

Max. Range: +/-180 degrees

Approx. LSB: 0.0439 degrees

Data Bits: 17 to 28 = 12

+ = Nose Up

Sign Bit: 29

Pad Bits: 11 to 16

Transmit Interval (mSec): 50 to 100

Data Type: 2’s Complement Binary

SDI Bits: 9, 10

6.2.45 Right Body Angle of Attack (225)

Body Angle of Attack

Source: IOC

LABEL (Octal) 225

Units: degrees

Max. Range: +/-180 degrees

Approx. LSB: 0.0439 degrees

Data Bits: 17 to 28 = 12

+ = Nose Up

Sign Bit: 29

Pad Bits: 11 to 16

Transmit Interval (mSec): 50 to 100

Data Type: 2’s Complement Binary

SDI Bits: 9, 10

6.2.46 VOR/ILS Frequency (034)

VOR/ILS Frequency

Source: ARINC 710 ILS

LABEL (Octal) 034

Units: MHz

Max. Range: 108 - 117.95MHz

Approx. LSB: 10 kHz

Data Bits: See NOTE

+ = N/A

Sign Bit: N/A

Pad Bits: N/A

Transmit Interval (mSec): 167 to 333

Data Type: Binary Coded Decimal (BCD)

SDI Bits: 9, 10

NOTE: This input is used to indicate if the VOR/ILS receiver is tuned to an ILS frequency, or to a VOR frequency.
BIT #14 will be set to a ‘0’ for all VOR frequencies, and to a ‘1’ for all ILS frequencies, by the tuning information source.

6.2.47 PFD Mode Select Word (163)

PFD MODE SELECT WORD – Type 4

Source: PFD via IOC

LABEL (Octal) 163

Units: N/A

Max. Range: N/A

Approx. LSB: N/A

Data Bits: See NOTE 2 and 3

+ = N/A

Sign Bit: N/A

Pad Bits: N/A

Transmit Interval (mSec): See NOTE 1

Data Type: Discrete

SDI Bits: N/A

NOTE 1: Transmit Interval for data from PFD via IOC is 250 mSec Maximum.
NOTE 2: BITS 25 to 28 contain Binary Code for Displayed Data Source, as listed below.
NOTE 3: BITS 19/20 indicate MDA selection status and BIT 21 indicates DH selection status, as listed below.

PFD Mode Select Word

BIT NO.

DEFINITION

19, 20

MDA Display Selection
Bit 19

Bit 20

0

0

MDA not selected

1

0

MDA selected

X

1

Not used

21

DH Display Selection

0

DH Not Selected

1

DH Selected