Body pitch rate (326), Body roll rate (327), Minimum descent altitude \(170\) – ioc scaling – Honeywell MK VI User Manual

Page 290: Normal angle of attack (236)

Advertising
background image

Honeywell

MK VI MK VIII EGPWS Installation Design Guide

Proprietary notice on title page applies

CAGE CODE: 97896

SCALE: NONE

SIZE: A

DWG NO: 060-4314-150

REV:

SHEET

290

22

Timed Audio Inhibit (momentary)

23

Reserved for EGPWS Test command Bit

24

Steep Approach activated (alternate action)

25-28

Terrain Display Range (as specified in the table below)

29

Not Used

BITS 25 to 28 = Terrain Display Range (0.5 to 2000 NM) format as follows:

DISPLAY RANGE BIT ASSIGNMENTS

Bits 28-25

DEFINITION

Bits 28-25

DEFINITION

0000

0.5 NM

1000

150 NM

0001

1.0 NM

1001

200 NM

0010

2.5 NM

1010

300 NM

0011

5.0 NM

1011

500 NM

0100

10 NM

1100

1000 NM

0101

25 NM

1101

2000 NM

0110

50 NM

1110

600 NM

0111

100 NM

1111

1200 NM

6.2.49 Body Pitch Rate (326)

Body Pitch Rate

Source: AHRS / IOC

LABEL (Octal) 326

Units: Deg/Sec

Max. Range: +/-128 Degrees/Sec

Approx. LSB: 0.0156 Deg/Sec

Data Bits: 16 to 28 = 13

+ = Nose Up

Sign Bit: 29

Pad Bits: 11 to 15

Transmit Interval (mSec): 10 to 20

Data Type: 2’s Complement Binary

SDI Bits: 9, 10

6.2.50 Body Roll Rate (327)

Body Roll Rate

Source: AHRS / IOC

LABEL (Octal) 327

Units: Deg/Sec

Max. Range: +/-128 Degrees/Sec

Approx. LSB: 0.0156 Deg/Sec

Data Bits: 16 to 28 = 13

+ = Right Wing Down

Sign Bit: 29

Pad Bits: 11 to 15

Transmit Interval (mSec): 10 to 20

Data Type: 2’s Complement Binary

SDI Bits: 9, 10

6.2.51 Minimum Descent Altitude (170) – IOC Scaling

Minimum Descent Altitude

Source: IOC

LABEL (Octal) 170

Units: Feet

Max. Range:

±

65,536 Feet

1

Approx. LSB: 1 Foot

Data Bits: 13 to 28 = 16

+ = Above Sea Level (ASL)

Sign Bit: 29

Pad Bits: 9 to 12

Transmit Interval (mSec): 200

Data Type: 2’s Complement Binary

SDI Bits: N/A

2

Note 1: Some IOC configurations may only provide positive ranges (0 to 65536 feet), however the EGPWS supports both

positive and negative ranges (

±

65,536 feet) for all configurations.

Note 2: This label may be provided in a configuration with a single DH input or in conjunction with a selected MDA

input. For those configurations which provide DH and MDA on separate labels format 3 applies (Format 1 is 0/0
SDI, Format 2 is Left SDI used and Format 3 is no SDI.)

6.2.52 Normal Angle of Attack (236)

Normal Angle of Attack

Source: IOC

LABEL (Octal) 236

Units: N/A

Max. Range: 0 to 1

Approx. LSB: 0.000031

Data Bits: 14 to 28 = 15

+ = N/A

Sign Bit: N/A

Pad Bits: 11 to 13, 29

Transmit Interval (mSec): 80

Data Type: 2’s Complement Binary

SDI Bits: 9, 10

Advertising
This manual is related to the following products: