Latitude fine (120) - gps, Longitude fine (121) - gps, Selected course (100) - ioc – Honeywell MK VI User Manual

Page 292: Dh/mda selected \(170\) – dau scaling, Digital data, arinc 575, Static air temperature (213)

Advertising
background image

Honeywell

MK VI MK VIII EGPWS Installation Design Guide

Proprietary notice on title page applies

CAGE CODE: 97896

SCALE: NONE

SIZE: A

DWG NO: 060-4314-150

REV:

SHEET

292

6.2.59 Latitude Fine (120) - GPS

Latitude Fine - GPS

Source: ARINC 743(A) GPSSU

LABEL (Octal) 120

Units: Degrees

Max. Range: +/-0.000172 Deg

Approx. LSB: 8.38E

-8

Deg

Data Bits: 18 to 28 = 11

+ = N/A

Sign Bit: 29

Pad Bits: 11 to 17

Transmit Interval (mSec): 1000 Maximum

Data Type: 2’s Complement Binary

SDI Bits: 9, 10

6.2.60 Longitude Fine (121) - GPS

Longitude Fine - GPS

Source: ARINC 743(A) GPSSU

LABEL (Octal) 121

Units: Degrees

Max. Range: +/-0.000172 Deg

Approx. LSB: 8.38E

-8

Deg

Data Bits: 18 to 28 = 11

+ = N/A

Sign Bit: 29

Pad Bits: 11 to 17

Transmit Interval (mSec): 1000 Maximum

Data Type: 2’s Complement Binary

SDI Bits: 9, 10

6.2.61 Selected Course (100) - IOC

Selected Course (BNR)

Source: IOC

LABEL (Octal) 100

Units: Degrees/180

Max. Range: +/-180 Degrees

Approx. LSB: 0.8789 Degrees

Data Bits: 18 to 28 = 11

+ = Clockwise from North

Sign Bit: 29

Pad Bits: 11 to 17

Transmit Interval (mSec): 100 to 500

Data Type: 2’s Complement Binary

SDI Bits: 9, 10

6.2.62 DH/MDA Selected (170) – DAU Scaling

DH/MDA Selected

Source: DAU

LABEL (Octal) 170

Units: Feet

Max. Range (for DH):
+/-4096 feet

Max. Range (for MDA):
+/-16384 feet

Approx. LSB: 1 foot

Data Bits (for DH):
17 to 28 = 12

Data Bits (for MDA):
15 to 28 = 14

+ = Above Ground Level (ASL)

Sign Bit: 29

Pad Bits: 11

Transmit Interval (mSec): 1000

Data Type: 2’s Complement Binary / Discrete

SDI Bits: 9, 10

Note: If Signal Displayed bit 13=1, MDA Selected is mapped to bit 14. SSM for this word uses the discrete word format.

6.3 Digital Data, ARINC 575

ARINC 575 data is very similar to the low speed ARINC 429 data described in the previous sections, but is one
generation earlier in the aircraft serial data definition. As such, there is NO SDI Field, and the SIGN/STATUS Matrix for
2’s Complement Binary data is different, and is given below for reference.

SIGN/STATUS Matrix: The number of BITS, and the meaning of these BITS, varies depending on the type of data in
the ARINC 575 word.

ARINC 575 BINARY (BNR) DATA

BIT 31

BIT 30

DEFINITION

0

0

Plus, North, East, Right, To, Above

0

1

Failure Warning

1

0

No Computed Data (NCD)

1

1

Minus, South, West, Left, From, Below

6.3.1 Static Air Temperature (213)

STATIC AIR TEMPERATURE

Source: ARINC 575 ADC

LABEL (Octal) 213

Units: Degrees Celsius

Max. Range: 512 Degrees C.

Approx. LSB: 0.5 Degree

Data Bits: 20 to 29 = 10

+ = Above ZERO

Sign Bit: Part of SSM

Pad Bits: 9 to 19

Transmit Interval (mSec): 500 Maximum

Data Type: 2’s Complement Binary

SDI Bits: N/A

Advertising
This manual is related to the following products: