Serial control interface (sci) status word 1 (ff) – Honeywell MK VI User Manual

Page 296

Advertising
background image

Honeywell

MK VI MK VIII EGPWS Installation Design Guide

Proprietary notice on title page applies

CAGE CODE: 97896

SCALE: NONE

SIZE: A

DWG NO: 060-4314-150

REV:

SHEET

296

DISPLAY RANGE BIT ASSIGNMENTS

DISPLAY MODE BIT ASSIGNMENTS

1

Bits 4 - 7

Range

Bits 4 - 7

Range

Bits 1-3

Display Mode

Displayable

0100

0.5 NM

0110

150 NM

000

STBY

NO

0010

1.0 NM

1100

200 NM

001

WX

YES

1111

2.5 NM

1010

300 NM

010

MAP

NO

1011

5.0 NM

0001

500 NM

011

FLIGHT PLAN

NO

1101

10 NM

0101

1000 NM

100

TEST

NO

1001

25 NM

0011

2000 NM

101

WX/T

YES

1110

50 NM

0000

spare

110

CYC

NO

1000

100 NM

0111

spare

111

TRB

NO

1

Display Mode used for “bolt-on” EDZ displays only.

6.5.1.2 Serial Control Interface (SCI) Status Word 1 (FF)

Status Word 1

Source: Map Electronics Unit (MEU)

LABEL (Hex) FF

Units: N/A

Max. Range: N/A

Approx. LSB: N/A

Data Bit: 1 – 8

+ = N/A

Sign Bit: N/A

Pad Bits: N/A

Transmit Interval (mSec): See above

Data Type: Discrete

SDI Bits: N/A

STATUS WORD BIT ASSIGNMENTS

BIT

DEFINITION

1

SECTOR SCAN *

2

TARGET ENABLE

3

P-450

4

ERASE

5

VAR GAIN

6

SLAVE

7

RIGHT

8

0

(Always zero in data word)

* Sector Scan used for “bolt-on” EDZ displays only.

6.5.2 Honeywell RS-232 Serial Control Interface for DC811 Up/Down Range

The DC811 controller transmits a 6 byte data packet with spacing between bytes of 16.67 mSec. Each byte consists of one
start bit (low), 8 data bits with least significant bit (LSB) first; an EVEN parity bit and one stop bit (high). The LSB of the
first packet byte is set to 1 to indicate the start of the packet (the other 5 bytes will have the LSB set to 0). The data rate for
this bus is 7.8125 KBS

±

0.01%. Depressing the Up or Down Range button will cause an Up or Down Range bit to be set

for 1 packet period (approximately 100 mSec). After an Up or Down transition no additional changes will be allowed for
approximately ½ second.

DC811 Data Packet

EGPWS Up/Down Ranges Supported

in Nautical Miles

BYTE

BIT

DESCRIPTION

2.5

1

0

1=Start of packet flag

5

2

10

3

25*

4

6

1=Range increment

50

5

1

1=Range decrement

100

6

* (default on power up)