Mode 6 callouts discrete #1 (272), Mode 6 callouts discrete #2 (273) – Honeywell MK VI User Manual

Page 306

Advertising
background image

Honeywell

MK VI MK VIII EGPWS Installation Design Guide

Proprietary notice on title page applies

CAGE CODE: 97896

SCALE: NONE

SIZE: A

DWG NO: 060-4314-150

REV:

SHEET

306

7.1.1.3 Mode 6 Callouts Discrete #1 (272)

Data:

Discrete

Label:

272 Octal

Significant Bits:

(see table below)

Sign Bit:

N/A

Transmit Interval:

100 msec ± 10%

BIT NO

WARNING MESSAGE (1 = voice on)

11

MINIMUMS

* 12

DECISION HEIGHT

* 13

APPROACHING MINIMUMS

* 14

APPROACHING DECISION HEIGHT

* 15

ZERO (Not supported)

16

TEN

17

TWENTY

18

THIRTY

19

FORTY

20

FIFTY

* 21

SIXTY

* 22

EIGHTY

23

ONE HUNDRED

24

TWO HUNDRED

25

THREE HUNDRED

* 26

MINIMUM

* 27

PLUS HUNDRED

* 28

DECIDE

* 29

FIFTY ABOVE

NOTE (*): Bits 12 - 15, 21, 22 and 26 - 29 will be set to zero, Not supported.

7.1.1.4 Mode 6 Callouts Discrete #2 (273)

Data:

Discrete

Label:

273 Octal

Significant Bits:

(see table below)

Sign Bit:

N/A

Transmit Interval:

100 msec ± 10%

BIT NO

DEFINITION (1 = voice on)

11

FOUR HUNDRED

12

FIVE HUNDRED (NORMAL, SMART or ABOVE FIELD)

13

ONE THOUSAND

* 14

700 HZ TONE

* 15

960 HZ TONE

* 16

1400 HZ TONE

* 17

2800 HZ TONE

18

BANK ANGLE (pause) BANK ANGLE

* 19

THIRTY FIVE

* 20

TWENTY FIVE HUNDRED

* 21

RADIO ALTIMETER

* 22

FIVE

23

FIVE HUNDRED ABOVE (ABOVE FIELD)

* 24

(SPARE)

* 25

(SPARE)

* 26

(SPARE)

* 27

FLAPS (pause) FLAPS

* 28

AUTOPILOT

* 29

SPEED BRAKE (pause) SPEED BRAKE

NOTE (*): Bits 14 - 17, 19 – 22, and 24 - 29 will be set to zero. Not supported.

Advertising