Shadin 2000 (cat. 2 id 10) – Honeywell MK VI User Manual

Page 61

Advertising
background image

Honeywell

MK VI MK VIII EGPWS Installation Design Guide

Proprietary notice on title page applies

CAGE CODE: 97896

SCALE: NONE

SIZE: A

DWG NO: 060-4314-150

REV:

SHEET

61

3.4.4 Shadin 200 0 (Cat. 2 ID 10)

Air Data Type 10 (Shadin 2000 or equivalent) is a low speed, digital ARINC 429 signal having the air data labels
203, 204, 206, and 212. Total Air Temperature is from a dedicated (EGPWS) 500-ohm probe using +5 volt
excitation from the MK VI/MK VIII EGPWC.

39

38

A

B

J2

ARINC 429 Air Data

ARINC 429 Bus - Hi

ARINC 429 Bus - Lo

EGPWS MK VI / MK VIII

A

B

ARINC 429 Low Speed

Air Data Bus

(+)

(-)

Temp. Input

Chassis Ground

+5V Excitation

500 ohm

Temperature

Probe

25

63

44

53

J1

Shadin2000.vsd

Cat 2

Bus 1

Bus 2

Vendor PN

ID

A

B

A

B

962830-1,2,3

10

J2-7

J2-8

962830A-1,2,3
962830A-X-S-4
962830A-X-S-5

10

J1-40

J1-22

NOTE:

The connector pin numbers given in the Table above are to the best knowledge of Honeywell EGPWS engineering. Please
contact the manufacturer’s customer service to confirm your installation.

Advertising
This manual is related to the following products: