Analog glideslope interface (cat. 9 id 0,1,5) – Honeywell MK VI User Manual

Page 95

Advertising
background image

Honeywell

MK VI MK VIII EGPWS Installation Design Guide

Proprietary notice on title page applies

CAGE CODE: 97896

SCALE: NONE

SIZE: A

DWG NO: 060-4314-150

REV:

SHEET

95

3.11.5 Analog Glid eslope Interface (Cat. 9 ID 0,1,5)

J1

ILS Receiver

EGPWS MK VI / MK VIII

GS Valid +28

11

+

-

Low Level

GS Valid

+28

GND

ILS

Tuned

+

-

GS Deviation

65
46

30
10

39
20

Super Flag +28V

+

-

Delayed ILS Mode
ILS Energize

GS Flag
(Low Level)

+Up
+Dn

GS Deviation

Analog-ILS-1.vsd

LOC Valid +28

48

LOC Val +28V

+

-

LOC Deviation

30
10

+L

+R

LOC Deviation

GS Inhibit (BC) +28

38

Backcourse

GS Inhibit (BC) GND

19

Backcourse

GS Valid

LOC Valid

ILS Tuned

Deviation

Vendor Model

Cat. 9

ID

SuperFlag

+28V

Low Level

Flag

SuperFlag

+28V

GND

GS +up

+dn

LOC +R

+L

Honeywell
KNR 6030

5

J1003-27

J1003-21
J1003-22

J1002-50

J1002-18

J1003-8
J1003-9

J1002-39
J1002-40

Honeywell
KNR 660

1

P1-e
P1-q

P1-k

P1-T
P1-V

Honeywell
KNR 634

1

5

P6342-50

P6342-34
P6342-18

P6342-49

P6341-17

P6342-36
P6342-35

P6342-23
P6342-7

Honeywell
KGM-691

0

P692-W

P692-S
P692-T

P692-a

P692-B
P692-C

Honeywell
KNR 600A

1

P601-e
P601-q

P601-A

P601-k

P601-r
P601-s

P601-m
P601-n

Collins
51RV-1, 51RV-4( )

5

TP-27

2

TP-21
TP-22

BP-50

BP-18

TP-8
TP-9

BP-39
BP-40

Collins
VIR-30, -31, -32

5

P1-17

P1-9
P1-13

P2-18

P2-40

P1-5
P1-1

P2-10
P2-13

Honeywell
VNS 41A

5

P1001-60

P1001-101

J1001-56

J1001-90
J1001-23

J1001-38
J1001-92

Honeywell
RNA-34A

5

TP-27

TP-21

BP-50

BP-18

TP-8
TP-9

BP-39
BP-40

Honeywell
KN 53

1

P2-13
P2-R

P2-12

P2-P
P2-14

Honeywell
KN 72

P1-2
P1-10

Honeywell
RNZ 850

5

P1-A74

P1-B60
P1-B106

P1-B91

P1-B64

P1-B79
P1-B75

P1-B78
P1-B75

Honeywell
KX-155/165

1

P901-U
P901-R

P401-14

P401-8

P901-S
P901-T

P901-s

(KX-165)

P901-k (only

NOTE:

The connector pin numbers given in the Table above are to the best knowledge of Honeywell EGPWS engineering. ePlease
contact the manufacturer’s customer service to confirm your installation.

1

066-1078-00, -01, -04, -05, -10, -11, -14 and –15 only.

2

51RV-4( ) only.

Advertising
This manual is related to the following products: