Category 10 – attitude input select, Roll angle – Honeywell MK VI User Manual

Page 98

Advertising
background image

Honeywell

MK VI MK VIII EGPWS Installation Design Guide

Proprietary notice on title page applies

CAGE CODE: 97896

SCALE: NONE

SIZE: A

DWG NO: 060-4314-150

REV:

SHEET

98

3.12 Category 1 0 – Attitude Input Select

Category 10 defines the Roll Angle interface.

Appendix E Table 5.3.10 defines the Attitude Input Select type and identifies the first MK VI/VIII EGPWS version
in which the option was available (see the Effectivity entry).

Appendix E Tables 5.3.10-x, where x is the Attitude Input Select Type number, define the format and electrical
interfaces required to support each Attitude Input Select Type.

3.12.1 Roll Angle

Roll Angle is used for Bank Angle callout and Terrain Awareness display. Each leg of the Roll Synchro is
required. The sign is used to determine left/right wing down. This input improves the TAD look ahead algorithm.

3.12.2 Analog Pitc h & Roll Angle (Synchro) (Cat. 10 ID 0,2,4)

1

21

2

J1

Vertical Gyro

X

Y

X

Y

Roll Synchro

Roll Angle

Z

Z

Attitude Validity

5

7

6

X

Y

X

Y

Pitch Synchro

Pitch Angle

Z

Z

68

+28 = Valid

Analog-VG.vsd

EGPWS MK

VI / MK VIII

Vendor Model

Attitude

Pitch Synchro (Note 1)

Roll Synchro (Note 1)

Vertical Gyro

Valid +28

X

Y

Z

X

Y

Z

Aeronetics

RVG

801

P1-U

P1-A

P1-B

P1-C

P1-D

P1-E

P1-F

Collins AHC-85( )

P1-13

P2-50

P2-51

P2-52

P2-42

P2-43

P2-44

Collins 332D-11

P1-N

P1-A

P1-B

P1-C

P1-D

P1-E

P1-F

Honeywell HG1075

J1B-G3

J1B-C9

J1B-C10

J1B-C11

J1B-D9

J1B-D10

J1B-D11

Honeywell HG1095

J1B-G3

J1B-C9

J1B-C10

J1B-C11

J1B-D9

J1B-D10

J1B-D11

JET VG-208

P1-U

P1-A

P1-B

P1-C

P1-D

P1-E

P1-F

King KVG-350

GG/FF

X

Y

Z

P

Q

R

Litef LTR-81

MP-A11

MP-B1

MP-B2

MP-B3

MP-B4

MP-B5

MP-B6

Litef LCR-92 & 93

Note 2

J3-11

J3-40

J3-26

J3-16

J3-39

J3-25

Sperry VG-14A

GG/FF

X

Y

Z

P

Q

R

Sperry VG-311

P1-45

P1-5

P1-4

P1-6

P1-7

P1-8

P1-9

Note 1:

The connector pin numbers given in the Table above are to the best knowledge of Honeywell EGPWS engineering. Please
contact the manufacturer’s customer service to confirm your installation.

Note 2:

See LCR installation manual.