5.3 Host Commands

SMART error logging

If the device detects an unrecoverable error during execution of a command
received from the host, the device registers the error information in the SMART
Summary Error Log (see Table 5.18) and the SMART Comprehensive Error Log
(see Table 5.19), and saves the information on media.

The host issues the SMART Read Log Sector sub-command (Features field = D5h,
Sector Number field = 01h, Sector Count field = 01h) and can read the SMART
Summary Error Log.

The host issues the SMART Read Log Sector sub-command (Features field = D5h,
Sector Number field = 02h, Sector Count field = 33h) and can read the SMART
Comprehensive Error Log.

Table 5.18 Data format of SMART Summary Error Log (1/2)

Byte(hex) Item

00

Version of this function

01

Pointer for the latest "Error Log Data Structure"

02 to 0D

Forth last command data structure

0E to 19

Third last command data structure

1A to 25

Second last command data structure

26 to 31

Last command data structure

32

Device Control field value

33

Features field value

34

Sector Count field value

35

Sector Number field value

36

Cylinder Low field value

37

Cylinder High field value

38

Drive/Head field value

39

Command field value

3A to 3D

Error log data
structure

Command data
structure

Elapsed time after the power-on
sequence (unit: ms)

C141-E280