5.3 Host Commands

Table 5.41 Data format of Read Log Ext log page 11h

Byte(hex) Item

00 to 03

Reserved

04 to 05

Counter 1 Identifier

06 to 09

Counter 1 Value

0A to 0B

Counter 2 Identifier

0C to 0F

Counter 2 Value

... ...

4C to 4D

Counter 10 Identifier

4E to 51

Counter 10 Value

52 to 53

Counter 0 Identifier

54 to 1FE

Reserved

1FF Check

sum

Table 5.42 Counter Identifier information

Identifier Description

0

No counter value : marks end of counters in the page

1

Command failed due to an ICRC error

2

Data FIS R_ERR ending status (transmitted and received)

3

Data FIS R_ERR ending status (transmitted)

4

Data FIS R_ERR ending status (received)

5

Non-data FIS R_ERR ending status (transmitted and received)

6

Non-data FIS R_ERR ending status (transmitted)

8

Non-data FIS retries (transmitted)

9

Transitions from drive PhyRdy to drive PhyNRdy.

A

Signature Device to Host Register FIS sent due to a COMRESET.

B

CRC errors within the FIS (received)

D

Non-CRC errors within the FIS (received)

F

Data FIS R_ERR ending status due to CRC errors (received)

10

Data FIS R_ERR ending status due to non-CRC errors (received)