5.3 Host Commands

Table 5.29 FEATURE CONTROL COMMAND

Byte(hex) Name Value

Description

00, 01

Action Code

0004h

FEATURE CONTROL COMMAND

0001h

Set New State

0002h

Return Current State

Current Feature Control State is displayed in SN/SC
field.

02, 03

Function

Code

0003h

Return Option Flag

Current Option Flag is displayed in SN/SC field.

0001h Write

Cache

0002h Write

Reordering

04, 05

Feature Code

0003h

Set time interval for temperature logging

Feature Code = 0001h (Set Write Cache)

0001h: Allow write cache operation to be determined

by ATA Set Feature command.

0002h: Force Write Cache enabled.

0003h: Force Write Cache disable.

Feature Code = 0002h(Set Write Reordering)

0001h: Enable Write Reordering

0002h: Disable Write Reordering

06, 07

New State

(2 byte)

Feature Code = 0003h(Set time interval)

0000h: Invalid

0001h-FFFFh: Logging interval in minutes

(ex.) 0001h:

Temperature data collection

interval is 1min.

000Fh:

Temperature data collection

interval is 15min.

08, 09

Option Flag

(2 byte)

Bit 15-1: Reserved

Bit0: 1 =

Maintain the state at

COMRESET/Power cycle.

0 =

Revert to default setting at

COMRESET/Power cycle.

0A to 1FF

(Reserved)

-

Reserved