4 command protocol – FUJITSU MHZ2250BJ User Manual

Page 249

Advertising
background image

5.4 Command Protocol

5.4 Command Protocol

The host should confirm that the BSY bit of the Shadow Block Status register of
the device is 0 prior to issue a command. If BSY bit is 1, the host should wait for
issuing a command until BSY bit is cleared to 0.

Commands can be executed only when the DRDY bit of the Status register is 1.
However, the following commands can be executed even if DRDY bit is 0.

EXECUTE DEVICE DIAGNOSTIC

INITIALIZE DEVICE PARAMETERS

Note: Each FIS type is referred to as follows in this section.

FIS (Frame Information Structure) type

Abbreviation

Register - Host to Device

RegHD

Register - Device to Host

RegDH

DMA Active - Device to Host

DMA Active

DMA Setup - Device to Host or Host to Device
(Bidirectional)

DMA Setup

Set Device Bits - Device to Host

SetDB

BIST Active - Bidirectional

BIST Active

PIO Setup - Device to Host

PIO Setup

Data - Host to Device or Device to Host (Bidirectional)

DATA

C141-E280

5-175

Advertising
This manual is related to the following products: