FUJITSU MHZ2250BJ User Manual

Page 156

Advertising
background image

Interface

SCT READ DATA (SN = E1h, FR = D5h)

This command reads the data specified with SCT SET COMMAND and number
of sectors specified Sector Count field.

28-bit command

At command issuance (Shadow Block Registers setting)

CM 1

1

0

1

0

0

0

0

DH x

x

x

DV

xx

CH

CL

SN

SC

FR

Key (C2h)

Key (4Fh)

E1h

xx

D5h


At command completion (Shadow Block Registers contents to be read)

ST Status

information

DH

x

x x

DV

xx

CH

CL

SN

SC

ER

xx

xx

xx

xx

Error information

SCT READ DATA Command issue procedure.

1. Issue the SCT set command of action code 0005h.

2. Issue the SCT READ DATA command and receive the HDA temperature

data from the device.

5-82