Battery setting examples – Fostex PD606 User Manual

Page 176

Advertising
background image

176

Location Recorder Model PD606

Chapter 8: MENU mode/BATTERY SETUP menu

<Battery setting examples>

<Example 1>:

The [DC-IN] power is normally used while a battery set to battery mount 1 is standby
for backup.

Power priority:

DC-IN,

Active battery:

BATT1

BATT1 is on

standby.

DC-IN is active.

DC-IN is

disconnected.

BATT1 is active.

BATT1 is on

standby.

DC-IN is restored.

[BATT1] indicator is unlit.

[BATT1] indicator is lit.

[BATT1] indicator is unlit.

Status information

display

Status information

display

Status information

display

<Example 2>:

The battery mounted on battery mount 1 is normally used while the [DC-IN] is on
standby for backup.

Power priority:

BATT.,

Active battery:

BATT1

BATT1 is active.

BATT1 battery is

being replaced.

BATT1 battery

replacement

finished.

DC-IN is on standby.

Status information

display

Status information

display

Status information

display

DC-IN is active.

DC-IN is on standby.

[BATT1] indicator is lit.

[BATT1] indicator is unlit.

[BATT1] indicator is lit.

Pop up window

Pop up window

Pop up window

Pop up window

Advertising