Location Recorder Model PD606

Chapter 3: Names and Functions

5.

[WORD IN] termination switch

Terminates the word input signal by setting the switch to "ON".

6.

[WORD/VIDEO IN] and [WORD OUT] connectors (BNC type)

The [WORD/VIDEO IN] connector receives word or video clock. It automatically
detects the clock type (word or video).
The [WORD OUT] connector feeds a word clock.

7.

[DIGITAL I/O] connector (D-sub 25-pin/female)

Receives and feeds AES/EBU or S/P DIF digital signals.

It automatically detects the digital audio input format (AES/EBU or S/P DIF).
You can set the digital input channels in the SETUP menu.

Signal

Input 1/2

Input 3/4
Input 5/6

Input 7/8

Output 1/2
Output 3/4
Output 5/6
Output 7/8

Frame GND

Open

Hot

Cold

1
2
3
4
5
6
7
8

14
15
16
17
18

19

20
21

10, 12, 13, 22,
23, 24, 25

9, 11

Terminal

treatment

Open

GND

• The pin assignment is compatible with the 25-pin D-sub connectors provided on

the Fostex 8350 and Yamaha equipment.

• Recommended connection cable:

DBK-258, DB-25 (M), TO 4XLR (M), AND 4XLR (F), 5M (16.5FT.), AES/EBU DIGITAL
AUDIO TRANSFER CABLE HOSA TECHNOLOGY,INC.

8.

Angle adjustment arm

1

14

13

25

10.

[PARALLEL] connector (MINI DIN 8-pin)

This connector accepts parallel remote signals for controlling the PD606 externally.

You can control the following nine operations remotely.

1

2

3

4

5

6

7

8

9

PLAY

STOP

RECORD

REWIND

F. FORWARD

CUE point registration

PAUSE

FILE

FILE

9.

[9P-REMOTE] connector (D-sub 9-pin/female)

Not currently supported. Prepared for the future expansion.