GE MDS Intrepid-HC HP Installation Guide

1-6

Assembling the Hanger Kit

The Hanger Kit is used to connect two RFUs and OCBs to the Pole Mount Kit. It consists of a single metal plate.

To assemble the Hanger Kit together with the RFU and OCB:

1. Place the RFU on the floor and hold it upright, as shown in the photo below.

2. Place the Hanger Kit in line with the OCB, as shown in the illustration below, and fasten the Kit to the OCB

using 3 large (M-10 type) screws.

Allen

Head

Screws

Hanger Bend
(to place on
the Pole Kit)

Main

Extension

Diversity

Extension

Three Screws
Fastening the
Hanger Kit to
the OCB

Advertising