3-3

SITE ACCEPTANCE CHECKLIST

(continued)

4. OUT-DOOR UNIT

Type of RFU mount:

(Direct or Remote mount)

RFU is securely mounted to the antenna or pole

OK

RFU is grounded as per installation instructions

OK

RFU‘s polarization is as per link requirements

OK

RFU is installed properly and has no physical damage

OK

For Remote-Mount Only:

Remote mount kit is securely mounted to the pole

OK

Flexible waveguide has no physical damage and connectors
are sealed

OK

All flexible waveguide bolts are secured using washers and
lock-washers, as appropriate

OK

Flexible waveguide is secured to the pole

OK

6. COAX CABLE

Overall cable length:

Cable type:

N-Type connectors assembled properly on the cable

OK

Cable connected securely to RFU and IDU

OK

Cable connector is weather-proofed (sealed) at the RFU

OK

At the RFU, cable has a service/drip loop to prevent
moisture from entering the connector

OK

Cable is secured using suitable restraints to fixed points at
regular intervals (0.5 m recommended)

OK

Cable has no sharp bends, kinks, or crushed areas. All
bends are per manufacturer specifications

OK

Grounding/lightning protection is as per site specifications

OK

Lightning protection type and model:

Cable point-of-entry to building/shelter is weather-proof

OK

Cable ends are properly labeled

OK