2-2

MDS Intrepid-HC HP Installation and Operation

- Setting up external alarms

Connecting the Line Interfaces

Initial Setup using the Craft Terminal

The following procedures are performed after the RFU and antenna are installed.

Connecting to the IDU via Serial Port

Turn the IDU power switch ON.

On the front panel of the IDU, the DRWR LED should be lit green.

To set up the HyperTerminal connection:

1.

Connect the RS-232 port of your computer to the RS-232 (9-pin) port on the IDU front panel. This port is
labeled “Terminal”.

2. Select

Start, Programs, Accessories, Communication, HyperTerminal.

3. Double-click

the

HyperTerminal application icon.

4. For

Connection Description, type Terminal, and click OK.

5. In

the

Connect Using field (Phone Number), select Direct to Com 1, and click OK.

6. In

the

Port Settings tab (Com 1 Properties), specify the following settings:

Bits per second - 19,200

Data bits - 8

Parity - None

Stop bits - 1

Flow control - Hardware

7. Click

OK.

8.

After you connect to the terminal, to enter the terminal setup program, press Enter.

9. For

password,

use

admin.