2-26

MDS Intrepid-HC HP Installation and Operation

first hitless fault. When the fault is cleared, the MUX will receive data from two sources: the +1 modem, and
its own modem, meaning the next fault in this channel will be errorless (if other carriers will fail, the data will
be hitless).

Revertive = Carrier#X
MUX number X will always receive two sources: the +1, and its own, unless there is a fault in another carrier.
If MUX number X receives two sources, and a fault occurs, the switch is errorless. In all the other cases, the
switch is hitless.

7. For

Revertive Switch Timeout, specify the period (in seconds) after which the revertive mode will be

activated.

8. For

High Priority Threshold, click the drop-down list and select the criteria upon which the system will

perform a switch to the channel you chose as high priority.

The options include: Baseband Loss of Frame, Baseband Excessive BER, Baseband Signal Degrade, and Early
Warning

9.

In the priority table, designate the high priority channel(s). A high priority channel will be switched first when
the criteria chosen for the threshold is met, even if a major fault occurs in a different channel.

The Priority Level options include:

Normal - regular operation according to the N+1 mechanism

High Priority

Not Protected – stand-alone channel without protection

Specifying System Information

Note: To specify system information, you must perform the following steps in all three IDCs in the Intrepid-HC
HP/T IDU:

1. Select

File, System, Information., or click the System Information icon

.