GE HC HP User Manual

Page 78

Advertising
background image

3-4

MDS Intrepid-HC HP Installation and Operation

SITE ACCEPTANCE CHECKLIST

(continued)

7. FLEXIBLE WAVEGUIDE

Flexible WG type:

Flexible WG is connected securely to RFU and Antenna

OK

Flexible WG connector is weather-proofed (sealed) at the
RFU

OK

At the RFU, the flexible WG has a service/drip loop to
prevent moisture from entering the connector

OK

Flexible WG is secured using suitable restraints to fixed
points at regular intervals (0.5 m recommended)

OK

Flexible WG has no sharp bends, kinks, or crushed areas.
All bends are per manufacturer specifications

OK

Flexible WG ends are properly labeled

OK

8. IN-DOOR UNIT

IDU is securely mounted to the rack

OK

IDU is located in a properly ventilated environment

OK

IDU fans are functional and air flow to the fans is not
disrupted

OK

IDU and rack are grounded as per site specifications

OK

Traffic cables and connections are properly terminated as
per manufacturer/cable instructions

OK

All cabling is secured, tidy, and visibly labeled

OK

9. DC POWER SUPPLY - Two Inputs

Measured DC voltage input to the IDU:

(-40.5 to -72 VDC)

Power-Supply maximum current:

(at least 3 Amperes)

Power-Supply is properly grounded

OK

DC power backup type:

IDU DC connector is secure and the DC input leads are
correctly terminated (no bare wires are visible)

OK

IDU DC connector (+) and (GND) leads are shorted and
GND is grounded

OK

10. RACK INSTALLATION

Rack is mounted to the shelter floor with four screws

OK

Rack is mounted to the shelter wall with two screws

OK