Motorola GT10 User Manual

Page 164

Advertising
background image

GT10/GT30

9.2

What to Do If Something Unusual Occurs (GT30)

141

Related

Solution

Cause

Problem

Cannot

transfer data

from GTWIN

1) The screen transfer cable is not con-

nected.

2) The PC and GT30 COM. port are con-

nected.

1) Confirm that the screen transfer cable

is correctly and firmly connected.

2) Connect to TOOL port with screen

transfer cable.

GTWIN HELP

* Screen is

blank (power

supply and

substitution

settings

above are

correct)

* An

incorrect

screen is

displayed

(error codes

and

erroneous

date and

time items

noted above

do not

apply)

* Switch

doesn’t work

(grid and

validity

settings

noted above

are correct)

An error has occurred in the GT30 sys-

tem.

1) After confirming the safety of the de-

vice, etc., turn off the power supply

and then turn it on again. The GT30

CPU will be reset.

2) If 1) produces no change, bring up the

system menu and initialize the

memory (F–ROM), then transfer data

again from GTWIN to the GT30.

CAUTION:

When doing this, all base screen data,

GT30 setting data, keyboard screen

data, and bitmap data will be lost. Be-

fore doing this, make sure all data has

been backed upage

3) If 2) produces no change, set the op-

erating mode setting switches 2, 3 and

4 on the rear of the GT30 to ON and

reset the power supply.

CAUTION:

When doing this, all of the contents will

revert to those in effect at the time of

shipping, and all of the GT30 memory

contents will be cleared. Before doing

this, make sure all data has been

backed upage

page 130

Advertising