Sysmac c series (direct connection to cpu) – Motorola GT10 User Manual

Page 89

Advertising
background image

GT10/GT30

4.12 Connecting with a PLC by Omron Corp.

66

SYSMAC C series (direct connection to CPU)

CPU *1

Usable cables

GT series

C200HS

SRM1–C02

CQM1–CPU11

CQM1–CPU42

CPM1–20CDR–A

CQM1H–CPU21 *2

Isolation cable by Omron

Corporation

CQM1–CIF01

GT10/GT30

*1 This is connected to the peripheral port.

*2 The CS1W–CN114 cable by Omron Corporation is required.

CAUTION

Please be aware that, because only one peripheral port is provided

with the CQM1–CPU11, it cannot be used at the same time as a PLC.

SYSMAC α series (using link interface)

CPU

Link I/F

Wiring diagram

GT series

C200HX–

CPU85–Z

CPU64

CPU44

C200HE–

CPU42

C200HG–

CPU63

CPU43

C200HW–COM06

D–sub 9–pin on Omron PLC side

SD

SD

RD

RD

RS

RS

CS

CS

GND

GND

GT main unit side

Pin no.

Abbreviation

1

FG

2

SD

3

RD

4

RS

5

CS

Pin no. Abbreviation

6
7

GT10/GT30

C200HE–

CPU42–Z

RS232C port on

CPU unit

7
8
9

SG

C200HX–

CPU64–Z

C200–LK201–V1

1

FG

2

SD

3

RD

4

RS

5

CS

D–sub 25–pin on Omron PLC side

Pin no. Abbreviation

SD

SD

RD

RD

RS

RS

CS

CS

GND

GND

GT main unit side

Pin no. Abbreviation

6
7

SG

.
.
20

ER