Programming Model

http://www.motorola.com/computer/literature

4-25

4

Scrub Timer Counter (Bits 7-0)

This register reflects the current value in the Scrub Timer counter bits 7-0.

Scrub Address Counter (Bits 26-24)

This read/write register is the Scrub Address counter. Each time the
scrubber performs a scrub memory cycle, the Scrub Address counter
increments. For an entire scrub, the Scrub Address counter starts at 0 and
increments until it reaches the DRAM size that is indicated by the
MEMSIZ pins. Writes to this address update the Scrub Address counter;
reads to this address yield the value in the counter. The ability to read and
write this counter is provided for test purposes. Note that if scrubbing is in
process, the Scrub Time On/Time Off register should be set for the
minimum time on and the maximum time off during any writes to this
register. This register reflects the current value in the Scrub Address
counter bits 26-24.

ADR/SIZ

1st $FFF43048/2nd $FFF43148 (8-bits)

BIT

31

30

29

28

27

26

25

24

NAME

ST7

ST6

ST5

ST4

ST3

ST2

ST1

ST0

OPER

R/W

R/W

R/W

R/W

R/W

R/W

R/W

R/W

RESET

0 PLS

0 PLS

0 PLS

0 PLS

0 PLS

0 PLS

0 PLS

0 PLS

ADR/SIZ

1st $FFF4304C/2nd $FFF4314C (8-bits)

BIT

31

30

29

28

27

26

25

24

NAME

0

0

0

0

0

SAC26

SAC25

SAC24

OPER

R/W

R/W

R/W

R/W

R/W

R/W

R/W

R/W

RESET

X

X

X

X

X

0 PLS

0 PLS

0 PLS