Error Conditions

http://www.motorola.com/computer/literature

1-57

1

MPU Local Bus Time-out

DMAC VMEbus Error

DMAC Parity Error

Description:

An error occurred while the MPU was attempting to access
a local resource.

MPU Notification:

TEA is asserted during the MPU access.

Status:

Bit 7 of the MPU Status and DMA Interrupt Count register
(actually in the DMAC Status register).
Address

$FFF40048

Comments:

The Local Bus timer timed out. This usually indicates the
MPU tried to read or write an address at which there was
no resource. Otherwise, it indicates a hardware problem.

Description:

The DMAC experienced a VMEbus error during an
attempted transfer.

MPU Notification:

DMAC interrupt (when enabled)

Status:

The VME bit is set in the DMAC Status register (address
$FFF40048 bit 1).

Comments:

This indicates the DMAC attempted to access a VMEbus
address at which there was no resource or the VMEbus
slave returned a BERR

signal.

Description:

Parity error while the DMAC was reading DRAM.

MPU Notification:

DMAC interrupt (when enabled)

Status:

The DLPE bit is set in the DMAC Status register (address
$FFF40048 bit 5).

Comments:

If the TBL bit is set (address $FFF40048 bit 2), the error
occurred during a command table access; otherwise the
error occurred during a data access.