Diags get state subcommand, Format, Return codes – Sun Microsystems FIRE V40Z User Manual

Page 132

Advertising
background image

110

Sun Fire V20z and Sun Fire V40z Servers, Server Management Guide • May, 2004

Diags Get State Subcommand

Description: Returns the state of the platform-diagnostics control server.

Format

Command format:

diags get state

If the result returned from the command is that the platform is up and ready for
diagnostics, then you can submit platform diagnostic tests for execution.

Success Text message –

The Platform Diagnostics are up and are available to

receive test requests.

Error Text Message –

The Platform Diagnostics are not up.

Return Codes

TABLE C-4

lists the return codes for this subcommand.

TABLE C-4

Return Codes for Subcommand diags get state

Return Code

ID

Description

NWSE_Success

0

Command successfully completed.

NWSE_InvalidUsage

1

Invalid usage: bad parameter usage, conflicting options
specified.

NWSE_DeviceError

25

Unable to read or write to the device.

Advertising