Diags run tests subcommand, Format – Sun Microsystems FIRE V40Z User Manual

Page 134

Advertising
background image

112

Sun Fire V20z and Sun Fire V40z Servers, Server Management Guide • May, 2004

Diags Run Tests Subcommand

Description: Submits one or more diagnostic tests for execution.

Format

Command format:

diags run tests [ [{ -n | --name} TEST NAME ] [{-a| --all}]

[-H | --noheader] [-P | --noprogress] [{-m | --module} MODULE NAME]

[-v | --verbose]

TABLE C-7

lists the arguments for this subcommand.

The following data displays after a test is run:

Submitted Test Name

Test Handle

NWSE_InvalidArgument

4

One or more arguments were incorrect or invalid.

NWSE_NoPermission

6

Not authorized to perform this operation.

NWSE_MissingArgument

7

Missing argument(s).

TABLE C-7

Arguments for Subcommand diags run tests

Arguments

Description

{ -n | --name}

Specifies the specific test(s) to execute. Run diags get tests
for a list of individual test names.

{-a | --all}

Specifies that all tests are to be executed. Run diags get
tests

for a list of all available tests. Specifying no arguments

also runs all tests for each device in the server.

{-H |--noheader}

Suppresses header output.

{-P | --noprogress}

Suppresses progress dots when waiting for test results.

{-m | --module}

Specifies that only tests for the specified module are to be
executed. Run diags get tests for a list of modules.

[-v | --verbose]

If specified, the Test Details display following the test result
line.

TABLE C-6

Return Codes for Subcommand diags get tests

Return Code

ID

Description

Advertising
This manual is related to the following products: