Sun Microsystems FIRE V40Z User Manual

Page 40

Advertising
background image

18

Sun Fire V20z and Sun Fire V40z Servers, Server Management Guide • May, 2004

Enabling IPMI LAN Access on a Solaris-Based x86 Server
(In-Band)

1. If the server is powered off, boot the local OS.

2. Log in to the server and authenticate as the user root.

3. Using IPMItool, configure the network setting for the SP by using the following

commands.

Note –

For more information on the syntax for IPMItool commands, refer to

“Syntax” on page 30

.

# ipmitool -I lipmi lan set 6 ipaddr

ipaddr

# ipmitool -I lipmi lan set 6 netmask

netmask

# ipmitool -I lipmi lan set 6 defgw ipaddr

gwipaddr

# ipmitool -I lipmi lan set 6 password

ipmipasswd

Alternate Method for Enabling IPMI LAN Access (Out-of-
Band)

1. Using an SSHv1 client or SSHv2 client, log in to the IP address of the SP.

2. Authenticate as the newly created management user (see

“Part II: Securing the

Service Processor” on page 13

”).

# ssh

spipaddr -l spuser

3. Enable IPMI LAN access and assign a password when prompted.

# ipmi enable channel lan

# exit

Note –

This password will be referred to as ipmipasswd in subsequent examples.

4. Using IPMItool, test the IPMI LAN access.

# ipmitool -I lan -H

spipaddr -P ipmipasswd chassis status

Advertising
This manual is related to the following products: