Lights out management (lom), Description, Further information – Sun Microsystems FIRE V40Z User Manual

Page 52: Syntax

Advertising
background image

30

Sun Fire V20z and Sun Fire V40z Servers, Server Management Guide • May, 2004

Lights Out Management (LOM)

On these servers, Lights Out Management is performed through IPMItool, a utility
for controlling IPMI-enabled devices.

Description

IPMItool is a simple command-line interface (CLI) to servers that support the
Intelligent Platform Management Interface (IPMI) v1.5 specification. It provides the
ability to:

■

Read the Sensor Data Record (SDR) and print sensor values

■

Display the contents of the System Event Log (SEL)

■

Print information about Field Replaceable Units (FRUs)

■

Read and set LAN configuration parameters

■

Perform chassis power control

Originally written to take advantage of IPMI-over-LAN interfaces, IPMItool is also
capable of using a system interface, as provided by a kernel device driver such as
OpenIPMI.

Further Information

■

For up-to-date information about IPMItool, visit:

http://ipmitool.sourceforge.net/

■

For more information about the IPMI specification, visit:

http://www.intel.com/design/servers/ipmi/spec.htm

■

For more information about the OpenIPMI project (MontaVista IPMI kernel
driver), visit:

http://openipmi.sourceforge.net/

Syntax

The syntax used by IPMItool is as follows:

ipmitool

[-ghcvV] -I lan -H

address [-P password] expression

ipmitool

[-ghcvV] -I open

expression

Advertising
This manual is related to the following products: