Sun Fire V20z and Sun Fire V40z Servers, Server Management Guide • May, 2004

SP Update Diags Subcommand

Description: Updates the current version of diagnostics available.

While the SP functions normally without access to an external file system, a file
system is required to enable several features, including diagnostics. The SP software
uses a default version of diagnostics. However, if a new version is released and
stored on the Network Share Volume, you must explicitly point to that new version
to use it.

Format

Command format:

sp update diags {-p | --path} <PATH_TO_DIAGS_FOLDER>

TABLE H-98

lists the argument for this subcommand.

Return Codes

TABLE H-99

lists the return codes for this subcommand.

TABLE H-98

Argument for Subcommand sp update diags

Argument

Description

{-p | --path}

Points to the location of the new diagnostics.

TABLE H-99

Return Codes for Subcommand sp update diags

Return Code

ID

Description

NWSE_Success

0

Command successfully completed.

NWSE_InvalidUsage

1

Invalid usage: bad parameter usage, conflicting options
specified.

NWSE_InvalidArgument

4

One or more arguments were incorrect or invalid.

NWSE_UnknownError

15

Miscellaneous error not captured by other errors.