Sun Fire V20z and Sun Fire V40z Servers, Server Management Guide • May, 2004

power

Performs a chassis control command to view and change
the power state.

status

Shows the current status of the chassis power.

on

Powers on the chassis.

off

Powers off chassis into the soft off state (S4/S5 state).
NOTE: This command does not initiate a clean shutdown
of the operating system prior to powering off the server.

cycle

Provides a power-off interval of at least 1 second.
No action should occur if chassis power is in S4/S5 state,
but it is recommended to check the power state first and
then only issue a power-cycle command if the server
power is on or in a lower sleep state than S4/S5.

reset

Performs a hard reset.

lan

print

channel

Prints the current configuration for the given channel.

set

channel
parameter

Sets the given parameter on the given channel.

ipaddr x.x.x.x

Sets the IP address for this channel.

netmask x.x.x.x

Sets the netmask for this channel.

macaddr
xx:xx:xx:xx:xx:xx

Sets the MAC adddress for this channel.

defgw ipaddr
x.x.x.x

Sets the default gateway IP address.

defgw macaddr
xx:xx:xx:xx:xx:xx

Sets the default gateway MAC address.

bakgw ipaddr
x.x.x.x

Sets the backup gateway IP address.

bakgw macaddr
xx:xx:xx:xx:xx:xx

Sets the backup gateway MAC address.

password pass

Sets the null user password.

user

Enables the user-access mode.

access [on|off]

Sets the LAN-channel-access mode.

ipsrc source

Sets the IP address source. As a source, you can indicate:
none = unspecified
static = manually configured static IP address
dhcp = address obtained by BMC running DHCP
bios = address loaded by BIOS or system software

TABLE 2-2

Expressions and Parameters for IPMItool (3 of 4)