20

Sun Fire V20z and Sun Fire V40z Servers, Server Management Guide • May, 2004

Daisy-Chaining the Servers

You can interconnect multiple servers in a daisy chain configuration by using the SP
connectors to form a management LAN as shown in

FIGURE 1-5

. This figure also

shows how the servers are connected to external LANs using the platform gigabit
connectors.

FIGURE 1-5

Daisy Chain Architecture

To interconnect the servers, you must use an RJ-45 cross-over cable. Cables can be
connected to either the top or bottom SP port. To configure servers in a daisy chain,
connect the first and last server in the chain to different switches.

Managed spanning-tree capable switches are required to redundantly connect both
the top and bottom of the chain. If the switch is not capable of spanning-tree
discovery, then only connect either to the top or the bottom of the chain, but not
both.

MGMT

SP

Server

= SP 10/100
connectors for
management LAN

= GB 100/1000
connectors for
external LANs

MGMT

SP

Server

MGMT

SP

Server

Mngmt
console

NFS/CIFS
server

Management LAN

Internet

Exter

nal LANs

Cross-o

v

e

r

Cross-o

v

e

r

Advertising