Sun Fire V20z and Sun Fire V40z Servers, Server Management Guide • May, 2004

Sensor Set Subcommand

Description: Allows you to set some of the data associated with a specific sensor or
a class of sensors.

Format

Command format:

sensor set [{-i | --id} SENSOR_ID [{-i | --id} SENSOR_ID] …]

{[{-C | --crithigh} VALUE] [[{-c | --critlow} VALUE]

[{-W | --warnhigh] VALUE] [{-w | --warnlow} VALUE] [{-v | --value}

{on|off}] | {-r | --reset}}

sensor set [{-t | --type] TYPE_ID] {[{-C | --crithigh} VALUE]

[[{-c| --critlow} VALUE] [{-W | --warnhigh] VALUE] [{-w | --warnlow}

VALUE] [{-v | --value} {on|off}] | {-r | --reset}}

sensor set [{-R | --resetall}]

TABLE G-4

lists the arguments for this subcommand.

TABLE G-4

Arguments for Subcommand sensor set

Arguments

Description

{-i | --id}

Specifies the specific sensor on which to operate. You can specify
multiple sensors by repeating --id.

{-t | --type}

Specifies the specific sensor class on which to operate (for
example, fan, voltage and so on).

{-C | --crithigh}

Specifies the critical high threshold value for the sensor.
• Setting the string to clear disables the threshold.
• Setting the string to reset sets the value to the original

factory-specified value.

• If the value specified ends in a percent sign (%), the threshold

is set to that percentage of the nominal value for the sensor.

• Any other value is interpreted as the actual value to which to

set the threshold.

{-c | --critlow}

Specifies the critical low threshold value for the sensor. Setting the
string to clear disables the threshold.

{-W | -warnhigh}

Specifies the warning high threshold value for the sensor. Setting
the string to clear disables the threshold.

{-w | --warnlow}

Specifies the warning low threshold value for the sensor. Setting
the string to clear disables the threshold.