Sun Microsystems FIRE V40Z User Manual

Page 44

Advertising
background image

22

Sun Fire V20z and Sun Fire V40z Servers, Server Management Guide • May, 2004

2. Press the Forward button until you reach the SP menu.

Menu:

SP menu

3. Press Select or Enter to display the SP menu’s options.

SP Menu:

Set SP IP info?

4. Press the Forward button until you reach the Update SP Flash menu option.

SP Menu:

Update SP Flash?

5. Press Select or Enter.

6. A string of 0s displays with the cursor at the left digit. Use the Forward and Back

buttons to increment or decrement a digit.

Note –

You are prompted for an IP address. If you attempt to update the SP

software using the operator panel when the IP address for the SP has not been set,
the update fails.

Note –

If you need to supply a port address, it can be any number between 0 and

65535. The leading 0s are removed.

See

Step 3

in

“Updating the Service Processor Base Component” on page 23

for more

information.

7. Press Select to move to the next digit.

8. Press Select when finished to return to the left-most column.

9. Press the button combination for Enter.