Enabling and configuring bios console redirection – Sun Microsystems FIRE V40Z User Manual

Page 89

Advertising
background image

Chapter 4

Further Management Information

67

Enabling and Configuring BIOS Console
Redirection

Note –

Console redirection is enabled by default in the BIOS.

If the default settings have been changed in the BIOS, the following procedure
explains how to change the console-redirection settings.

1. Boot or reboot the server.

2. When prompted, press <F2> to enter BIOS setup.

3. Select the Advanced menu from the category selections along the top.

4. Select Console Redirection.

Note –

Make note of all settings in this menu, as they are required for configuring

the remote-console access and the Serial Over LAN (SOL) feature.

5. Select I/O Device Configuration.

6. Select On-board COM A from the Port option to enable console redirection to

serial.

Ensure that COM A is enabled on I/O port 3F8, FRQ4.

■

To change the baud rate, you can select the desired bit rate from the Baud Rate
option.

■

To disable console redirection to serial, you can select Disabled from the Port
option.

7. Save the changes to the BIOS settings.

8. Press <F10> to exit the BIOS setup.

For the new settings to take effect, you must reboot the server.