Suburban Mfg REGAL INTENSIVE CARE UNIT 12019-01-NGFREP User Manual

Page 117

Advertising
background image

Form No. 702718 Rev. A March, 2005

105

Owner’s Manual - Regal Intensive Care Unit

Digital Display

(Floor Temperature,

Left & Right)

P/N 853843

There are two digital displays on the electronics compartment door,
one each for left floor temperature and right floor temperature. The
displays are identical and are removed and installed the same way.

CAUTION: Before proceeding, make sure the unit is
Off, and the electric power cord un-plugged.

Tool Required

„

13/64-in. wrench

Removal

1.

Make sure that the main on/off switch is Off and the
amber light in the switch is out.

2.

Unplug the power cord from the electrical outlet.

3.

Open the electronics compartment (refer to Page 57).

4.

Pull the 4-wire ribbon connector off the rear of the display
(Figure 117).

5.

With a 13/64-in. wrench, remove the four retaining nuts on
the rear of the digital display.

Figure 117. Inside View of Digital Display
Assembly

4-Wire Ribbon Connector

Retaining Nut (1 of 4)

Red

stripe on

this wire

Figure 118. Digital Display Parts

Bezel

Nuts

Ribbon

Cable

Printed

Circuit Board

Advertising