Form No. 702718 Rev. A March, 2005

61

Owner’s Manual - Regal Intensive Care Unit

Figure 70. Fuse Cap and Fuse

Fuse Cap

Fuse

Figure 69. Floor Temperature Fuses

Floor

Temperature

Fuses

Replacing Floor

Temperature Fuses

Two fuses are provided for protection of the left and right floor tem-
perature systems (Figure 68). Both fuses are 3AG fast-acting, 250 V,
2 amp. If you need replacement fuses you can order them from SSCI,
however, they are standard items and can be obtained faster and
cheaper at your local hardware or electronics supply store.

Removal

Press in on the fuse cap, then twist about one-quarter turn counter-
clockwise, and pull out the fuse cap and fuse (Figure 70).

Inspection

Inspect the thin, curly metal wire inside the transparent center
section of the fuse (Figure 70). If the wire is intact, the fuse is OK.
If the wire is burned or broken, the fuse is bad and must be re-
placed.

Installation

1.

Place either end of the fuse into the fuse cap.

2.

Engage the “ears” behind the fuse cap into the gaps in the
fuse holder.

3.

Press in on the fuse cap, and turn about one-quarter turn
clockwise until it snaps into place.