TIMER
11-11
Timer Pre-Scale Register
TPRE (0x004)
Access: Read/Write
31
30 29 28 27 26 25
24
−
−
−
−
−
−
−
−
R/W-0 R/W-0 R/W-0
R/W-0
R/W-0 R/W-0 R/W-0
R/W-0
23
22 21 20 19 18 17
16
−
−
−
−
−
−
−
−
R/W-0 R/W-0 R/W-0
R/W-0
R/W-0 R/W-0 R/W-0
R/W-0
15
14 13 12 11 10 9
8
−
−
−
−
−
−
−
−
R/W-0 R/W-0 R/W-0
R/W-0
R/W-0 R/W-0 R/W-0
R/W-0
7
6 5 4 3 2 1
0
PRESCALE[7:0]
R/W-1 R/W-1 R/W-1
R/W-1
R/W-1 R/W-1 R/W-1
R/W-1
W: Write
R: Read
-0: 0 After reset
-1: 1 After reset
-U: Undefined after reset
Pre-scale Value for Timer
PRESCALE
0x00~ 0xFF
NOTE
The PRESCALE register can be changed only when TEN is set to 0, in other words timer should be stop.
Timer input clock frequency (t
CLK
) = PCLK / (pre-scale value + 1)
pre-scale value = 0 – 255
For example)
PCLK = 90MHz
PRESCALE = 11