Protection option bits read register – Samsung S3F401F User Manual
Page 79

S3F401F_UM_REV1.00
INTERNAL FLASH ROM
5-19
Protection Option Bits Read Register
FPO (0x014)
Access: Read Only
31
30 29 28 27 26 25 24
FPODAT [31:24]
R-U
R-U R-U R-U R-1 R-U R-U R-U
23
22 21 20 19 18 17 16
FPODAT [23:16]
R-U
R-U R-U R-U R-U R-U R-1 R-U
15
14 13 12 11 10 9 8
FPODAT [15:8]
R-U
R-U R-U R-U R-U R-U R-U R-1
7
6 5 4 3 2 1 0
FPODAT [7:0]
R-U
R-U R-U R-U R-U R-U R-U R-U
W: Write
R: Read
-0: 0 After reset
-1: 1 After reset
-U: Undefined after reset
Smart Option
Protection Option bits read register data
0bXXXX_1XXX_(bit27:RDP)
XXXX_XX1X_(bit17:HDP)
XXXX_XXX1_(bit8:LDCP)
FPODAT
XXXX_ XXXX (at Fabrication)
NOTE
Reading the Protection Option Bits (LDCP(bit[8])/HDP(bit[17])/RDP(bit[27]) which are port of Flash
Memory) is possible only through the register FPO, because the bits of protection option cannot be read
like normal cell.