Kyocera FS-6700 User Manual

Page 163

Advertising
background image

5-18

Message

Corrective Action

FIT

(image FITting) flashes to indicate that a loss of raster data

occurred when the data was compressed to be fitted within the
currently available memory. Flashing

FIT

extinguishes automati-

cally when the job times out; the printer receives the next data
from the host computer; or if you press any key on the printer’s
control panel. Try adding more memory in the printer to prevent
this error.

Change of the resolution indicator from

600

to

300

(flashing)

means that the job in 600-dpi resolution was not able to run
within the currently available memory. The resolution reverts to

600

dpi automatically when the job times out; the printer receives

the next data from the host computer; or if you press any key on
the printer’s control panel. Try adding more memory in the printer
to prevent this error.

Processing

PAR FIT A4

Processing

PAR 600 A4

Processing

PAR 300 A4

5.5. Indicators and Messages

Advertising