C-16, Prescribe iie frpo d0 command – Kyocera FS-6700 User Manual

Page 215

Advertising
background image

C-16

H7: Buffer nearly-empty threshold

This is a percentage from 0 to 99. The factory setting is 70.

The factory settings of the buffer nearly-full and nearly-empty thresholds (H6 and H7) are subject
to change without notification.

The gap between the nearly-full and nearly-empty thresholds allows the computer to send a fairly
large amount of data in a continuous stream.

H8: Received-data buffer size

This is the size of the input buffer, specified in units of 10 K bytes. The factory-set value is 6
meaning 60 K bytes.

PRESCRIBE IIe FRPO D0 command

The PRESCRIBE IIe FRPO D0 command is provided to allow manipulating XON/XOFF when an
error has occurred on the serial interface. The following table summarizes the error status
corresponding to different D0 values.

Serial interface error

error not handled

error handled

Timing of XON transfer

XON sent every 3-5

D0 = 0 (default)

D0 = 1

to host while Ready or

seconds

Waiting

XON not sent

D0 = 10

D0 = 11

C.3. RS-232C/RS-422A Protocol