Value parameter, Table 11 value types, Table 12 group settings and values – Liebert POWER PROTECTION STATIC TRANSFER SWITCH User Manual

Page 87: Table 11, Value types, Table 12, Group settings and values

Advertising
background image

Communication Interfaces

79

Value Parameter

Item settings, depending on what they are, use various value types.
Table 11 provides a list of the possible value types and their description.

Table 12 shows the various groups, the settings contained within, and the type of value it requires.

Table 11

Value types

Type

Definition

Numeric

An integer numeric value in the units indicated by the item name. For example, a

System Voltage Rating of 480 would indicate 480 volts.

Scaled

Similar to the Numeric, this value type is an integer that has been scaled, usually to

remove decimal points that would normally appear within the value. In this case, a

value of 2.5 may actually be input as simply 25. For all Scaled types, the scaling

appears in Table 12.

String

Certain settings are represented by alphanumeric character strings, such as setting

the System Model Number to STS2.

Enumeration

This type uses an indexed list to represent possible choices. One example is the

Modem Baud Rate which uses a value of 0 to select 2400 bps, 1 for 9600 bps, and 2

for 19200 bps.

Bit-packed

This type of value uses a hexadecimal binary word, where each of the sixteen bits in

the word has the value of 1 (True) or 0 (False). Although somewhat difficult to use, it

packs a large amount of data within a single entry. A detailed description of this type

appears in section 12.1.3 - Setting Bitpacked Options with the Terminal on

page 81.

Event Masks

This type is a specially formatted and is used to customize the behavior of each fault

and alarm in the system. See 12.1.4 - Setting Event Masks with the Terminal on

page 83 for instructions on configuring Event Mask parameters.

Table 12

Group settings and values

Group

Item:

Description

Value Type

Value Notes

Group 1:

System

Ratings

1

Input Volts (PDU)

Integer

Set per system spec.

2

Volts

Integer

Set per system spec.

3

Current

Integer

Set per system spec.

4

Frequency

Scaled

Desired freq. x 10 (600 = 60 Hz)

Group 2:

System

Settings

1

Language

Enumeration

[Not supported at this time]

2

System Model Number

String

14 Character max.

3

System ID Number

String

8 Character max.

4

System Tag Number

String

8 Character max.

5

System Order Number

String

8 Character max.

6

Options_1

Bitpacked

14 Character max.

7

Autodial Primary Line

String

20 Character max.

8

Autodial Secondary Line

String

20 Character max.

9

Autodial Pager Number

String

20 Character max.

10

Autodial Pager PIN

String

10 Character max.

Group 2

11

Modem Init String

String

20 Character max.

(cont.)

12

Modem Baud Rate

Enumeration

0 = 2400, 1 = 9600, & 2 = 19200 bps

13

Modem LGS Check - Day

Bitpacked

14

Modem LGS Check - Time

Bitpacked

15

Comms Options 1

Bitpacked

See section 12.1.3.

16

Comms Options 2

Bitpacked

See section 12.1.3.

Advertising