Table 4-26, external modem (com port) options – Paradyne 9788 User Manual

Page 103

Advertising
background image

4. Configuration Options

9700-A2-GB20-20

December 2002

4-63

Configuring the COM Port to Support an External Modem

Select External Modem (Com Port) to display or change the configuration options
that control COM port external device call processing (see

Table 4-26, External

Modem (COM Port) Options

).

Main Menu

→Configuration→Management and Communication→

External Modem (Com Port)

NOTE:

A standard EIA-232 crossover cable is required when connecting an external
modem to the FrameSaver unit’s COM port. See

DB25-to-DB25 Crossover

Cable

or

DB9-to-DB25 Crossover Cable

in Appendix E,

Connectors, Cables,

and Pin Assignments, for cable pin assignments.

Table 4-26. External Modem (COM Port) Options

External Modem Commands

Possible Settings: Disable, AT
Default Setting: Disable

Specifies the type of commands to be sent over the COM port.

CAUTION: Do

not use this setting when an async terminal is connected to the COM

port (see

Table 4-25, Communication Port Options

).

Disable – Commands will not be sent over the COM port.

AT – Standard Attention (AT) Commands are sent over the COM port to control the
external device. All AT command strings will end with a carriage return (hex 0x0D) and a
line feed (hex 0x0A).

Dial-In Access

Possible Settings: Enable, Disable
Default Setting: Enable

Controls whether external devices can dial-in to the FrameSaver unit through the COM
port (based on the Port Use option setting).

Display Conditions – This option does not appear if External Modem Commands is
disabled.

Enable – Answers incoming calls and establishes connection to the remote terminal or
IP network.

Disable – Does not answer incoming calls.