Paradyne 9788 User Manual

Page 274

Advertising
background image

C. Router CLI Commands, Codes, and Designations

C-10

December

2002

9700-A2-GB20-20

[no] bridge-group

bridge-group

Minimum Access Level: Administrator
Command Mode: config-if, config-subif

Allows a user to apply or remove a set of bridge group parameters to/from an interface or
sub-interface. When a set of bridge group parameters is applied or removed at the
interface level, the command also applies to all sub-interfaces on the interface.

Example: no bridge-group

NOTE: If the bridge group is only required on specific sub-interfaces, remove the
bridge group from an interface and apply it at the sub-interface level.

bridge-group – Valid bridge group number 1 is applied to all interfaces by default. Any
sub-interfaces created on interfaces where the bridge group is applied inherit the bridge
group.

[no] bridge-group

bridge-group

{input-type-list

in-access-list-200num |

output-type-list

out-access-list-200num}

Minimum Access Level: Administrator
Command Mode: config-if

Allows a user to specify or remove an input or output Ethernet type code filter for an
interface. No bridge group filters are applied to interfaces by default.

Example: bridge-group 1 input-type-list 8069

NOTE: The order in which access-list filters are entered affects the order in which the
filters are applied. Each filter is applied in succession until all filters have been applied.
If no conditions match, a frame is discarded.

bridge-group – Valid bridge group number 1 is applied to all interfaces by default. Any
sub-interfaces created on interfaces where the bridge group is applied inherit the bridge
group.

input-type-list – Specify the filter applied to incoming Ethernet packets by type code.
Refer to

Table C-14, Ethernet Type Codes (Hex)

.

in-access-list-200num – The input type access list valid range for protocol type-code
access lists: 200–299.

output-type-list – Specify the filter applied to outgoing Ethernet packets by type code.
Refer to

Table C-14, Ethernet Type Codes (Hex)

, Ethernet Type Codes (Hex).

out-access-list-200num – The output type access list number valid range for protocol
type-code access lists: 200–299.

Table C-6.

Bridge Commands (2 of 2)

Advertising
This manual is related to the following products: