7. Operation and Maintenance

9700-A2-GB20-20

December 2002

7-37

Frame Relay LMI

(CSU/DSUs only)

LMI Protocol

The LMI protocol configured for the frame relay link. Normal
condition.

Status Msg Received

Number of LMI status messages received over the interface.
Normal condition.

Total LMI Errors

Number of LMI errors, including reliability errors, protocol errors,
unknown report types, unknown information elements, and
sequence errors.

Number of Inactives

Number of times the LMI has declared the frame relay link
Inactive.

Frame Relay HDLC Errors

Rx Total Errors

Total number of errors received on the interface, including:

Receive invalid frames (short frames, long frames, invalid
DLCIs, unknown DLCIs, and unknown errors)

Rx Total Discards

Receive errors (non-octet aligned frames, frames with CRC
errors, and Rx Overruns)

Rx Total Discards

Total number of discards received on the interface, including:

Resource errors

Rx Overruns

Frames received when the link was down

Inactive and disconnected DLCIs

Inactive destination DLCIs

Unknown EDLCIs

Rx Overruns

Number of Overruns received.

Rx Non-octet Frames

Number of Non-Octet frames received.

Rx CRC Errors

Number of Cycle Redundancy Check (CRC) errors received.

Tx Total Errors

Total number of errors transmitted on the interface, including
transmit discards and transmit overruns.

Tx Total Discards

Total number of discards transmitted on the interface, including
underrun flushes.

Tx Underruns

Number of underruns transmitted.

Table 7-16. Frame Relay Performance Statistics (2 of 2)

Statistic

What It Indicates