6. Security and Logins

9700-A2-GB20-20

December 2002

6-13

Creating a Login for the User Interface

A login is required to access the user interface if security is enabled.

Security is

enabled by configuration options for:

Communication Port Login Required

FTP Login Required

Telnet Login Required

Logins must be unique and are case sensitive. Up to six login ID/password
combinations can be created and each login ID has a specified access level.

Procedure

To create a login record:

1. Select Administer Logins.

Main Menu

→Control→Administer Logins

2. Select New, and set the following configuration options, as appropriate:

NOTE:

If you are locked out, see

Resetting the Unit and Restoring

Communication

in Chapter 8,

Troubleshooting.

3. Save your changes. You must save on this screen for updates to be valid.

When Save is complete, the cursor is repositioned at the Login ID field, ready
for another entry.

For information about SNMP security options, see

Configuring SNMP NMS

Security

in Chapter 4,

Configuration Options.

In the field . . .

Enter . . .

Login ID

1 to 10 ASCII characters.

Password

1 to 10 ASCII characters.

Re-enter Password

Password verification.

Access Level

Level-1 – Top level. User can add, change, and display
configuration options, save changes, and run device tests.
All functions from the Main Menu are available.

Level-2 – User can monitor and perform diagnostics and
display status and configuration option information. Main
menu displays Status, Test, and Configuration.

Level-3 – User can only monitor and display status and
configuration screens. Main menu displays Status and
Configuration only.

CAUTION: Make sure at least one login is set up for Level-1
access so you are not inadvertently locked out.

Advertising